You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
68 lines
2.1 KiB
68 lines
2.1 KiB
20 years ago
|
#
|
||
|
# IPMI device configuration
|
||
|
#
|
||
|
|
||
|
menu "IPMI"
|
||
|
config IPMI_HANDLER
|
||
|
tristate 'IPMI top-level message handler'
|
||
|
help
|
||
|
This enables the central IPMI message handler, required for IPMI
|
||
|
to work.
|
||
|
|
||
|
IPMI is a standard for managing sensors (temperature,
|
||
|
voltage, etc.) in a system.
|
||
|
|
||
|
See <file:Documentation/IPMI.txt> for more details on the driver.
|
||
|
|
||
|
If unsure, say N.
|
||
|
|
||
|
config IPMI_PANIC_EVENT
|
||
|
bool 'Generate a panic event to all BMCs on a panic'
|
||
|
depends on IPMI_HANDLER
|
||
|
help
|
||
|
When a panic occurs, this will cause the IPMI message handler to
|
||
|
generate an IPMI event describing the panic to each interface
|
||
|
registered with the message handler.
|
||
|
|
||
|
config IPMI_PANIC_STRING
|
||
|
bool 'Generate OEM events containing the panic string'
|
||
|
depends on IPMI_PANIC_EVENT
|
||
|
help
|
||
|
When a panic occurs, this will cause the IPMI message handler to
|
||
|
generate IPMI OEM type f0 events holding the IPMB address of the
|
||
|
panic generator (byte 4 of the event), a sequence number for the
|
||
|
string (byte 5 of the event) and part of the string (the rest of the
|
||
|
event). Bytes 1, 2, and 3 are the normal usage for an OEM event.
|
||
|
You can fetch these events and use the sequence numbers to piece the
|
||
|
string together.
|
||
|
|
||
|
config IPMI_DEVICE_INTERFACE
|
||
|
tristate 'Device interface for IPMI'
|
||
|
depends on IPMI_HANDLER
|
||
|
help
|
||
|
This provides an IOCTL interface to the IPMI message handler so
|
||
|
userland processes may use IPMI. It supports poll() and select().
|
||
|
|
||
|
config IPMI_SI
|
||
|
tristate 'IPMI System Interface handler'
|
||
|
depends on IPMI_HANDLER
|
||
|
help
|
||
|
Provides a driver for System Interfaces (KCS, SMIC, BT).
|
||
|
Currently, only KCS and SMIC are supported. If
|
||
|
you are using IPMI, you should probably say "y" here.
|
||
|
|
||
|
config IPMI_WATCHDOG
|
||
|
tristate 'IPMI Watchdog Timer'
|
||
|
depends on IPMI_HANDLER
|
||
|
help
|
||
|
This enables the IPMI watchdog timer.
|
||
|
|
||
|
config IPMI_POWEROFF
|
||
|
tristate 'IPMI Poweroff'
|
||
|
depends on IPMI_HANDLER
|
||
|
help
|
||
|
This enables a function to power off the system with IPMI if
|
||
|
the IPMI management controller is capable of this.
|
||
|
|
||
|
endmenu
|