Kernel driver lm78
|
||
|
==================
|
||
|
|
||
|
Supported chips:
|
||
|
* National Semiconductor LM78
|
||
|
Prefix: 'lm78'
|
||
|
Addresses scanned: I2C 0x20 - 0x2f, ISA 0x290 (8 I/O ports)
|
||
|
Datasheet: Publicly available at the National Semiconductor website
|
||
|
http://www.national.com/
|
||
|
* National Semiconductor LM78-J
|
||
|
Prefix: 'lm78-j'
|
||
|
Addresses scanned: I2C 0x20 - 0x2f, ISA 0x290 (8 I/O ports)
|
||
|
Datasheet: Publicly available at the National Semiconductor website
|
||
|
http://www.national.com/
|
||
|
* National Semiconductor LM79
|
||
|
Prefix: 'lm79'
|
||
|
Addresses scanned: I2C 0x20 - 0x2f, ISA 0x290 (8 I/O ports)
|
||
|
Datasheet: Publicly available at the National Semiconductor website
|
||
|
http://www.national.com/
|
||
|
|
||
|
Author: Frodo Looijaard <frodol@dds.nl>
|
||
|
|
||
|
Description
|
||
|
-----------
|
||
|
|
||
|
This driver implements support for the National Semiconductor LM78, LM78-J
|
||
|
and LM79. They are described as 'Microprocessor System Hardware Monitors'.
|
||
|
|
||
|
There is almost no difference between the three supported chips. Functionally,
|
||
|
the LM78 and LM78-J are exactly identical. The LM79 has one more VID line,
|
||
|
which is used to report the lower voltages newer Pentium processors use.
|
||
|
From here on, LM7* means either of these three types.
|
||
|
|
||
|
The LM7* implements one temperature sensor, three fan rotation speed sensors,
|
||
|
seven voltage sensors, VID lines, alarms, and some miscellaneous stuff.
|
||
|
|
||
|
Temperatures are measured in degrees Celsius. An alarm is triggered once
|
||
|
when the Overtemperature Shutdown limit is crossed; it is triggered again
|
||
|
as soon as it drops below the Hysteresis value. A more useful behavior
|
||
|
can be found by setting the Hysteresis value to +127 degrees Celsius; in
|
||
|
this case, alarms are issued during all the time when the actual temperature
|
||
|
is above the Overtemperature Shutdown value. Measurements are guaranteed
|
||
|
between -55 and +125 degrees, with a resolution of 1 degree.
|
||
|
|
||
|
Fan rotation speeds are reported in RPM (rotations per minute). An alarm is
|
||
|
triggered if the rotation speed has dropped below a programmable limit. Fan
|
||
|
readings can be divided by a programmable divider (1, 2, 4 or 8) to give
|
||
|
the readings more range or accuracy. Not all RPM values can accurately be
|
||
|
represented, so some rounding is done. With a divider of 2, the lowest
|
||
|
representable value is around 2600 RPM.
|
||
|
|
||
|
Voltage sensors (also known as IN sensors) report their values in volts.
|
||
|
An alarm is triggered if the voltage has crossed a programmable minimum
|
||
|
or maximum limit. Note that minimum in this case always means 'closest to
|
||
|
zero'; this is important for negative voltage measurements. All voltage
|
||
|
inputs can measure voltages between 0 and 4.08 volts, with a resolution
|
||
|
of 0.016 volt.
|
||
|
|
||
|
The VID lines encode the core voltage value: the voltage level your processor
|
||
|
should work with. This is hardcoded by the mainboard and/or processor itself.
|
||
|
It is a value in volts. When it is unconnected, you will often find the
|
||
|
value 3.50 V here.
|
||
|
|
||
|
In addition to the alarms described above, there are a couple of additional
|
||
|
ones. There is a BTI alarm, which gets triggered when an external chip has
|
||
|
crossed its limits. Usually, this is connected to all LM75 chips; if at
|
||
|
least one crosses its limits, this bit gets set. The CHAS alarm triggers
|
||
|
if your computer case is open. The FIFO alarms should never trigger; it
|
||
|
indicates an internal error. The SMI_IN alarm indicates some other chip
|
||
|
has triggered an SMI interrupt. As we do not use SMI interrupts at all,
|
||
|
this condition usually indicates there is a problem with some other
|
||
|
device.
|
||
|
|
||
|
If an alarm triggers, it will remain triggered until the hardware register
|
||
|
is read at least once. This means that the cause for the alarm may
|
||
|
already have disappeared! Note that in the current implementation, all
|
||
|
hardware registers are read whenever any data is read (unless it is less
|
||
|
than 1.5 seconds since the last update). This means that you can easily
|
||
|
miss once-only alarms.
|
||
|
|
||
|
The LM7* only updates its values each 1.5 seconds; reading it more often
|
||
|
will do no harm, but will return 'old' values.
|